In PIXERA 25.2, you can now use a SP Lens file crated in Stage Precision to adopt lens parameters in real time. This offers to calibrate the lens of a Camera in Stage Precision once and use it without piping the tracking data through Stage Precision in PIXERA. Instead you can hook up the tracking system via FreeD to PIXERA directly and use the SP Lens file to create FoV and lens distortion from incoming tracking values.
System Setup
First you have to setup your VP environment as usual with one or multiple LED screens and Studio Camera.
When basic setup is finished you can navigate to the inspector of the Studio Camera and you can fins Calibration section at the very bottom.

Select SP Lens in the calibration Mode drop down.
Afterwards select the SP Lens file itself by clicking on the file selector of the Lens Profile.
Now the Studio Camera will take in count the values provided by the Lens file and the incoming tracking data is manipulated using the SP lens file.
Tracking Setup
In PIXERA control you have to either use FreeD or SPNet module for incoming tracking data.
The loaded SP Lens file need normalized values from 0-100 from focus and zoom encoder. This can be done in Stage Precision when using the SPNet module.
When using FreeD module you have to make sure that Normalize Focus and Zoom is activated.
This will normalize the encoder values that can have a range from 0 - 65535 to 0-100 values.

Select the Port and Adapter IP you are using and double check the sending with your tracking system.
Reinitialize the FreeD module after those changes. IsOpen should turn to true and you should see now the correct Frequency in the getFreq field.

Switch to the UI of the module and click on Start Learning.

The ID of the FreeD Camera will pop up, and you can see the learned range for Zoom and Focus.
During learning phase make sure that you change focus and zoom of the camera lens to it's min an max values.

After doing so you should see the range of the learned values.
Now click on Update Config from Leaned Data, so that those values are stored internally to normalize the values.
By clicking on Update Actions from Leaned Data new action will be created in the module in the Camera folder.
Now it is time to link the tracking module with the Studio Camera.
Expand the Camera folder in the FreeD module and connect the function TransformationAndLensPropsExt with the according function of the Studio Camera (PIXERA → Screens → getStudioCamera → “name of the Camera” → setTransformationAndLensPropsExt)

PIXERA 25.2 | 15. September 2025 | O.H.